The total number of data samples per scan or per slice in CT is the:


A) number of data samples per view times the number of views.
B) number of views.
C) number of detectors plus the number of data samples per detector.
D) number of data samples per view plus the number of views.

E) None of the above
F) A) and D)

Correct Answer

verifed

verified

The high-voltage generators of slip-ring scanners are located in the gantry.

A) True
B) False

Correct Answer

verifed

verified

Which of the following refers to the size, shape, motion, and path traced by the X-ray beam as it scans the patient?


A) Beam geometry
B) Projection profile
C) Data acquisition
D) Detector tracing

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Which of the following X-ray tubes is most likely used in spiral/helical CT scanners?


A) A tungsten target fixed anode tube
B) A tungsten target rotating anode tube
C) A molybdenum target rotating anode tube
D) A rotating anode tube with a rhenium tungsten disk

E) C) and D)
F) All of the above

Correct Answer

verifed

verified

What design of collimation is influenced by the size of the focal spot?


A) Prepatient collimation
B) Postpatient collimation
C) Predetector collimation
D) Postdetector collimation

E) B) and D)
F) A) and D)

Correct Answer

verifed

verified

The speed with which a CT detector can detect an X-ray event and recover to detect another event is the:


A) response time.
B) stability.
C) efficiency.
D) dynamic range.

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

Which detector characteristic refers to the steadiness of the detector response?


A) Efficiency
B) Stability
C) Response time
D) Dynamic range

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

Which scanner results in a volume of the patient being scanned during a single breath-hold (rather than a single slice of tissue) ?


A) Spiral/helical scanner
B) Seventh-generation scanner
C) Second-generation scanner
D) First-generation scanner

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

Please match the following data acquisition concepts. All answer selections will be used just once. -Slip-ring design


A) Data acquisition system
B) Flashes of light
C) Beam hardening
D) Xenon gas
E) Slice thickness
F) Photodiode
G) Continuous gantry rotation

H) A) and F)
I) A) and E)

Correct Answer

verifed

verified

Please match the following data acquisition concepts. All answer selections will be used just once. -Semiconductor


A) Data acquisition system
B) Flashes of light
C) Beam hardening
D) Xenon gas
E) Slice thickness
F) Photodiode
G) Continuous gantry rotation

H) D) and G)
I) E) and G)

Correct Answer

verifed

verified

Fourth-generation CT scanners are characterized by:


A) rotate-translate motion and parallel beam geometry.
B) rotate-translate motion and fan-beam geometry.
C) fan-beam geometry and continuous rotation of X-ray tube and detectors
D) fan-beam geometry and complete rotation of X-ray tube around a stationary ring of detectors

E) B) and C)
F) A) and C)

Correct Answer

verifed

verified

Which CT scanner is based on a fan-beam geometry and complete rotation of the X-ray tube and detectors?


A) First-generation scanner
B) Second-generation scanner
C) Third-generation scanner
D) Fourth-generation scanner

E) All of the above
F) C) and D)

Correct Answer

verifed

verified

Which scanner is based on slip-ring technology?


A) Third-generation conventional scanner
B) Fourth-generation conventional scanner
C) Spiral/helical scanner
D) Fifth-generation scanner

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

Photodiodes are now used in CT scintillation detectors.

A) True
B) False

Correct Answer

verifed

verified

Which X-ray generator is used in modern CT scanners?


A) Single-phase half-wave rectified
B) Single-phase full-wave rectified
C) High-frequency generator
D) Three-phase, six-pulse generator

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

Anistrophic is a term used to describe detector channels that are equal in size.

A) True
B) False

Correct Answer

verifed

verified

Sixth-generation scanners are referred to as the cine CT scanner because of its high-speed acquisition for imaging the heart and circulation.

A) True
B) False

Correct Answer

verifed

verified

Which of the following is commonly used in gas-ionization CT detectors?


A) Xenon
B) Oxygen
C) Neon
D) Helium

E) A) and C)
F) All of the above

Correct Answer

verifed

verified

What category of multirow detector array utilizes an isotropic design?


A) Adaptive array detectors
B) Matrix array detectors
C) Unilateral array detectors
D) Identical array detectors

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

The purpose of collimation in CT is each of the following except:


A) create an homogenous beam.
B) to protect the patient.
C) to ensure a constant beam width at the detector.
D) to reduce scatter radiation.

E) B) and C)
F) A) and D)

Correct Answer

verifed

verified