Filters
Question type

Study Flashcards

Which instruction can best be used to turn an output coil on or off after the rung has been false for a desired time?


A) RTO
B) TON
C) ON OFF
D) TOF

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

For ControlLogix controllers the time base is fixed at 1 second.

A) True
B) False

Correct Answer

verifed

verified

The timer file for SLC 500 controllers is:


A) T1
B) T2
C) T3
D) T4

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

D

The only way to reset a TON instruction is to use a Reset (RES) instruction.

A) True
B) False

Correct Answer

verifed

verified

Timer instructions are found on all PLCs manufactured today.

A) True
B) False

Correct Answer

verifed

verified

The preset time of a TON timer instruction represents the amount of time that has elapsed from when the instruction became true.

A) True
B) False

Correct Answer

verifed

verified

The type of timer program shown is a: The type of timer program shown is a:   A) retentive on-delay. B) retentive off-delay. C) nonretentive off-delay D) nonretentive on-delay.


A) retentive on-delay.
B) retentive off-delay.
C) nonretentive off-delay
D) nonretentive on-delay.

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

Which one of the following timer parameters determines the time duration for the timing circuit?


A) Accumulated time.
B) Preset time.
C) Timer address.
D) Time base.

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

For the program shown, the timer starts timing when: For the program shown, the timer starts timing when:   A) PB1 is closed. B) PB2 is closed. C) both PB1 and PB2 are closed. D) either PB1 or PB2 is closed.


A) PB1 is closed.
B) PB2 is closed.
C) both PB1 and PB2 are closed.
D) either PB1 or PB2 is closed.

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

For the timer program shown, output C is switched ON when: For the timer program shown, output C is switched ON when:   A) power is applied. B) input A is closed. C) the timer is accumulating time. D) the accumulated value equals the preset value.


A) power is applied.
B) input A is closed.
C) the timer is accumulating time.
D) the accumulated value equals the preset value.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

A retentive timer must be completely timed out to be reset.

A) True
B) False

Correct Answer

verifed

verified

Cascading timers provide a method to extend the timing range.

A) True
B) False

Correct Answer

verifed

verified

True

For the programmed timer circuit shown the ____ bit of the timer functions similar to an instantaneous contact. For the programmed timer circuit shown the ____ bit of the timer functions similar to an instantaneous contact.   A) DN B) EN C) PB1 D) PB2


A) DN
B) EN
C) PB1
D) PB2

E) A) and C)
F) C) and D)

Correct Answer

verifed

verified

For the programmed timer circuit shown, when the switch is initially closed motor(s) _____ start(s) immediately. For the programmed timer circuit shown, when the switch is initially closed motor(s)  _____ start(s)  immediately.   A) M1 B) M2 C) M3 D) all of these


A) M1
B) M2
C) M3
D) all of these

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

The on-delay timed period for the timer shown would be: The on-delay timed period for the timer shown would be:   A) 3 seconds B) 4 seconds C) 20 seconds D) 200 seconds


A) 3 seconds
B) 4 seconds
C) 20 seconds
D) 200 seconds

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

In the hardwired circuit shown, the light will stay on: In the hardwired circuit shown, the light will stay on:   A) as long as S1 is closed. B) for 5 s after coil TD is energized. C) for 5 s after coil TD is de-energized. D) as long as S1 is closed and for 5 s after coil TD is de-energized.


A) as long as S1 is closed.
B) for 5 s after coil TD is energized.
C) for 5 s after coil TD is de-energized.
D) as long as S1 is closed and for 5 s after coil TD is de-energized.

E) A) and B)
F) A) and D)

Correct Answer

verifed

verified

The interconnecting of timers is commonly called:


A) grouping.
B) programming.
C) sequencing.
D) cascading.

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

The loss of logic continuity to either a TON or TOF timer causes the timer instruction to reset.

A) True
B) False

Correct Answer

verifed

verified

The instantaneous contacts of a timer have no time-delay period associated with them.

A) True
B) False

Correct Answer

verifed

verified

True

For the timer relay contact shown, when the relay coil is energized, there is a time delay before the contact opens. For the timer relay contact shown, when the relay coil is energized, there is a time delay before the contact opens.

A) True
B) False

Correct Answer

verifed

verified

Showing 1 - 20 of 70

Related Exams

Show Answer